BRV Between Room Ventilator
Directions for Use


Ventilator Placement


The ventilator may be placed on any common wall between the supply and return ducts. Be careful to select a section of wall that contains no studs, wiring or ductwork.


Installation

Slip the two sides of the ventilator apart and remove the square louvered grills. Use the round end of one of the tubes to trace a circle at the desired location on the wall. Cut out the round hole with a hole saw, jigsaw or drywall saw. Align the hole location on the other side of the wall, mark it and cut it. Assemble the two halves of the ventilator through the two holes to be sure that they will slide together. For standard walls (4 ½ inches thick), use the inner section of pipe provided. For shallower walls, remove the inner pipe section. For walls thicker than 6 inches, order additional tube sections as needed.

With both halves of the ventilator in place, mark two screw locations on opposite corners on each side of the wall. Remove the two sides of the ventilator and drill holes at the marked spots for the plastic anchors supplied in the hardware kit. Insert the anchors and use the provided one-inch screws to attach both sides. Replace the square louvered grills on each side of the installed wall sections. The ¼" screws provided in the hardware kit can then be used to secure the louvered grills to each side of the ventilator.